OWNER
S OPERATION AND INSTALLATION MANUAL
WARNING: Improper installation,
adjustment, alteration, service or main-
tenance can cause injury or property
damage. Refer to this manual for correct
installation and operational procedures.
For assistance or additional information
consult a qualified installer, service agency,
or gas supplier.
This appliance may be installed in an
aftermarket* permanently located, manufac-
tured (mobile) home, where not prohib-
ited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l Do not try to light any appliance.
l Do not touch any electrical switch; do not
use any phone in your building.
l Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
l If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, service agency or gas
supplier.
MN200EPC MN200EHPC
MN300EPC MN300EHPC
INFRARED VENT-FREE
NATURAL GAS
SPACE HEATER
WARNING: If the information in
this manual is not followed exactly, a
fire or explosion may result causing
property damage, personal injury, or loss
of life.
WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) from the
room in which it is installed. Provisions
for adequate combustion and ventilation
air must be provided. Refer to Air For
Combustion and Ventilation section on
page 5 of this manual.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM
HEATERS
Water vapor is a by-product of gas combustion.An
unvented room heater produces approximately one (1)
ounce (30ml) of water for every 1,000 BTUs
(.3KWs) of gas input per hour. Refer to page 4.
Installer: Please leave these instructions with the
consumer.
Consumer: Please retain these instructions for
future use.
Continental Appliance Inc./US Office
5 Musick 4600 Highlands Parkway S.E.
Irvine Suite# D/E
CA 92618 Smyrna GA 30080
TOLL FREE NUMBER: 1-877-886-5989
Nanjing PRO-COM Electric Appliance Co.,Ltd.
#6 Chuangye Road,High New Tech.Zone,
Great Bridge Road North,Nanjing,210061,China.
PR-MCL051-01-0506
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - MN300EPC MN300EHPC

OWNER’S OPERATION AND INSTALLATION MANUAL WARNING: Improper installation,adjustment, alteration, service or main-tenance can cause injury o

Pagina 2 - Table of Contents

10INSTALLATION*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tapis an acceptable alternative to test gauge con

Pagina 3 - LOCAL CODES

11Figure 13 -Equipment Shutoff ValvePressure Testing Heater GasConnections1. Open equipment shutoff valve (see Figure 13).2. Open

Pagina 4 - PRODUCT FEATURES

12OPERATING YOUR HEATERcontinuedAUTO ON: With burner off, pressTIMER button. Then press or tochange to the scheduled time, thenpress the TI

Pagina 5

13Figure 15- Manual ControlPush in gas control knob slightlyand turn clockwise to OFF.Do not use force. NOTE: Wait one(1) minute with control

Pagina 6 - " of the ceiling and

14 CLEANING AND MAINTENANCEDISCONNECT WIRING OFCONTROL MODULE1. Remove two screws from the lowerfront panel , pull the lower front panelforwar

Pagina 7

15Figure 24- Double Control System Diagram(Model MN200EHPC MN300EHPC)Figure 23-(Model MN300EPC)

Pagina 8

16Note: Dimensions listed are outer most points on the heater (includes grill). * For purposes of input adjustment.MN200EPC(MN200EH

Pagina 9 - CONNECTING TO GAS

17TROUBLESHOOTINGPOSSIBLE CAUSE1. No power to heater2. ON/off switch not ON3. Wire is damaged or loose4. Pilot electrode position is not correct5

Pagina 10 - INSTALLATION

18TROUBLESHOOTINGContinuedOBSERVED PROBLEMODS/pilot has flame, but burner(s)does not lightDelayed ignition of burner(s)Burner backfiring during

Pagina 11 - OPERATING YOUR

19TROUBLESHOOTINGContinuedREMEDY1. Ventilate room. Stop using odor causing products while heater is running2. Locate and correct

Pagina 12 - (childproof)

Table of ContentsSafety Information...2..Product Features...

Pagina 13 - APPLIANCE

20ILLUSTRATEDPARTS BREAKDOWNMN200EPC

Pagina 14 - WARNING:

21PARTS LISTMN200EPCThis list contains replaceable parts for your heater. When ordering replacementparts, following the instructions li

Pagina 15 - Figure 23

22ILLUSTRATEDPARTS BREAKDOWNMN200EHPC

Pagina 16 - SPECIFICATIONS

23PARTS LISTMN200EHPCThis list contains replaceable parts for your heater. When ordering replacementparts, following the instructions l

Pagina 17 - TROUBLESHOOTING

24ILLUSTRATEDPARTS BREAKDOWNMN300EPC

Pagina 18

25PARTS LISTMN300EPCThis list contains replaceable parts for your heater. When ordering replacementparts, following the instructions li

Pagina 19

26ILLUSTRATEDPARTS BREAKDOWNMN300EHPC

Pagina 20 - PARTS BREAKDOWN

27PARTS LISTMN300EHPCThis list contains replaceable parts for your heater. When ordering replacementparts, following the instructions l

Pagina 22

3SAFETY INFORMATION9. Do not use heater if any part has been under water. Immediately call a qualified service technician to

Pagina 23 - MN200EHPC

4PRODUCT FEATURESFigure1 Vent-Free HeaterWater vaporis a by-product of gas combustion. An vent-free room heater produces approximately one (1) ounce(

Pagina 24

5AIR FOR COMBUSTIONAND VENTILATIONPROVIDING ADEQUATEVENTILATIONThe following are excerpts fromNational Fuel Gas Code. NFPA54/ANSI Z223.1,

Pagina 25 - MN300EPC

6Rework worksheet, adding the space of the adjoiningunconfined space. The combined spaces must haveenough fresh air to supply all applia

Pagina 26

7LOCATING HEATERThis heater is designed for mount-ing on a wall, set on floor, awayfrom a wall. Purchase optional floormounting stan

Pagina 27 - MN300EHPC

8INSTALLATIONCONTINUEDMethods For Attaching MountingBracket To WallOnly use last hole on each endof mounting bracket to attachbracket

Pagina 28

9Installing Bottom Bracket(See Figure 10)1. Install bottom bracket to heater bottom with two screws. It may be more convienent to re

Comentarios a estos manuales